D116 Ultrasonic Flowmeter

· High performance at an affordable price
· Simply clamp-on outside of pipe for easy set up

· Save time with no pipe cutting or process shutdown

 

d116Overview
Ultrasonic flowmeter D116 liquid flow meter is optimized for customers still looking for high performance, but needing a lower-cost, less feature-rich option for dedicated clamp-on ultrasonic metering. 
Ultrasonic flowmeter D116 digital liquid flow meter optimizes the measurement of water as it flows in irrigation and other liquid applications.

Common applications include: d116 cu
· Water and wastewater measurements
· Leak detection in piping systems
· Contactless product recognition
· Interface detection
· Automated process control

Product Benefits
· Designed for water and general liquid flow metering applications
· Tolerant of liquids with small amounts of air bubbles or suspended solids
· No moving parts to clog or fatigue like turbine meters
· Transducers clamped to outside of pipe
· Permanent or temporary installations
· Immune to the process compatibility concerns
· Install meter during plant operations
· No process shut-downs, no leakage risks
· Operational safety and robustness
· Ideal for large line sizes
· Low maintenance, no moving parts, robust construction
· High zero stability, nearly drift free
· Mounting kit included to lock transducer into place
· Modular electronics enabling field upgrades
· SD card data logging capability
· Large display with push buttons, user-friendly menu
· Transducers are matched pair and temperature compensated
· Field validation/configuration to ensure operating performance
· Daily, monthly and yearly totalized flow rate
· Positive, negative and net flow totalizers (with user-selectable scale factors)
· Configurable pulse, analog and frequency outputs
· Fully field configurable
· Digital communications: RS232, RS485, Modbus RTU

picture D116

Specifications
Accuracy +/- 1.0% of reading from 0.03 ft/s to 16 ft/s ( 0.01 m/s to 5 m/s)

Repeatability +/- 0.3% of reading
· Wide turndown ratio
· Bi-directional flow range of 0.03 to 16 ft/s (0.01 to 5 m/s)
· Pipe sizes from 2 to 48 inches (50.8 mm to 1200 mm)
· Process pipe-wall temperature: 32°F to140°F (0°C to 60°C)
· Power supply: 10 to 24 VAC or 10 to 36 VDC at 1A

Output signals:
  4-20 mA 
Pulse (configurable)
Relay (configurable)
Digital communications: RS-232, RS-485, Modbus RTU

Materials:
  Enclosure NEMA 4X (IP65), die-cast aluminum
  Transducers IP68 (Encapsulated)

· Standard cable length: 30 ft (9 m), Maximum cable length: 100 ft (30 m)

D116 Ordering & Instruction Manual.pdf