Print

NR-Type Area Type Flow Meter (Rotameter)


NR typeOperation Principle
The variable area flow meter consists of a float & taper tube. The fluid flows through the taper tube and forces up to the float. The flow rate is measured as a function of the area of the opening. This area displayed on the float that is free to move to produce the varying area.

Technical Data

Measuring The Flow Rate For
Gases & Liquid
Chemical process system
Industrial flow system


Service condition
Viscosity: ≤ 3cP
Max. working temperature: Metal: 100°C; Plastic: 60°C

Max. working pressure:
(1) Body material: NRS: 15 kg/cm2,
NRI: 15 kg/cm2, NRV: 6 kg/cm2
(2) Glass tube: Borosilicate glass 6 kg/cm2
(3) P.C tube: 10 kg/cm2, Instant pressure: 15 kg/cm2


Alarm Switch Available (N.0)
Switch rating: AC 125V 0.5A / DC 100V 10W/
Max. DC 250V < 1mA
Accuracy: ±2.5% F.S

nr type data